The operational energy of the permanent magnet actuator is provided by the storage capacitor. The permanent magnet mechanism switch portable operation box enables closing or hierarchical operation of the permanent magnet switch when the secondary control system fault is faulty in the permanent magnet mechanism switch. The portable operating case is small, light, beautiful, easy to carry, less components, high reliability. The battery can be used as a backup power supply or a hand-shaker as a backup power supply, the portable operation box is that the power supply sector improves the supply of the power supply to operate the permanent magnet switch must match the tool.
The operational energy of the permanent magnet actuator is provided by the storage capacitor. The permanent magnet mechanism switch portable operation box enables closing or hierarchical operation of the permanent magnet switch when the secondary control system fault is faulty in the permanent magnet mechanism switch. The portable operating case is small, light, beautiful, easy to carry, less components, high reliability. The battery can be used as a backup power supply or a hand-shaker as a backup power supply, the portable operation box is that the power supply sector improves the supply of the power supply to operate the permanent magnet switch must match the tool.
The main technical parameters
Serial number | project | Hand-shaker | Battery-type portable box |
1 | Input voltage | AC 0 ~ 220V | AC220V |
2 | Operating voltage | DC110V / DC220V / DC380V (± 10%) | |
3 | Working voltage (battery) | / | DC12V / DC24V |
4 | Closing maximum output current | <120a | |
5 | Maximum output current | <120a | |
6 | Enter voltage | - | DC12V / DC24V (± 10%) |
7 | Closing delay | - | 0 ~ 1000 ms (can be set) |
8 | Divergence | - | 0 ~ 1000 ms (can be set) |
Machine power consumption (static) | - | <5W |
Note: Technical parameters exceed the scope of the previous table, please contact us
The main technical parameters
Serial number | project | Hand-shaker | Battery-type portable box |
1 | Input voltage | AC 0 ~ 220V | AC220V |
2 | Operating voltage | DC110V / DC220V / DC380V (± 10%) | |
3 | Working voltage (battery) | / | DC12V / DC24V |
4 | Closing maximum output current | <120a | |
5 | Maximum output current | <120a | |
6 | Enter voltage | - | DC12V / DC24V (± 10%) |
7 | Closing delay | - | 0 ~ 1000 ms (can be set) |
8 | Divergence | - | 0 ~ 1000 ms (can be set) |
Machine power consumption (static) | - | <5W |
Note: Technical parameters exceed the scope of the previous table, please contact us
Features
Compatible Single Double Steady Permanent Magnet Agency Switch. |
After the permanent magnet drive loop is faulty, the permanent magnetic circuit breaker is replaced by the controller. |
Small size, light weight, can be carried with it. |
Safe reliability, self-contained capacitor discharge circuit, to achieve rapid capacitance, improve capacitive safety, extend capacitive life |
Operating coil abnormal detection functions, with coil ports, coil abnormal detection can be performed by multimeter. |
Note: Technical parameters exceed the scope of the previous table, please contact us
Features
Compatible Single Double Steady Permanent Magnet Agency Switch. |
After the permanent magnet drive loop is faulty, the permanent magnetic circuit breaker is replaced by the controller. |
Small size, light weight, can be carried with it. |
Safe reliability, self-contained capacitor discharge circuit, to achieve rapid capacitance, improve capacitive safety, extend capacitive life |
Operating coil abnormal detection functions, with coil ports, coil abnormal detection can be performed by multimeter. |
Note: Technical parameters exceed the scope of the previous table, please contact us